Definitions

All Code Lockout Mode:

This feature is enabled by the Master code. When enabled, it restricts all user (except

Master)

code access. When attempting to enter a code while the unit is in Lockout, the

locked padlock

PIN

RED

will appear on the screen.

Automatic Re-lock Time:

After a successful code entry and the unit unlocks, it will automatically re-lock after

thirty (30) seconds.

Inside Indicator Light:

Located on the interior escutcheon. Shows active status (Locked) of lock and can be

enabled or disabled in the

(Main Menu selection #3).

Advanced Lock Settings

Language Setting Mode:

Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the

lock's voice prompts.

Low Battery:

When battery power is low, the Low Battery Warning indicator flashes

.      If battery power is

RED

completely lost, use the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction,
to terminals below the touchscreen for backup power option. Wake up the lock and enter your pin code to unlock
the door.

Master

Code:

It must be created

PIN

The Master

code is used for programming and for feature settings.

PIN

prior to programming the lock.

The Master code will also operate (unlock/lock) the lock.

Network Module Setting:

With the optional Network Module installed, this setting becomes available thru the

Main Menu (7) and allows the lock to connect with a network controller.

One Touch Locking:

When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-

lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is

in use

any

not

(disabled),

valid

code will re-lock the lock.

PIN

Previous:

While in Menu Mode, pressing this icon cancels the current operation and returns the user to the

previous step.

Privacy Mode:

Privacy mode is disabled by default. Enable Privacy mode by pressing the privacy button for 4

seconds to put the lock in do-not-disturb mode (all pin codes are disabled).

Shutdown Time:

The unit will shutdown (flashing

) for sixty (60) seconds and not allow operation after the

RED

wrong code entry limit (5 attempts) has been met.

Tamper Alert:

Audible alarm sounds if attempting to forcibly remove outside lock from door.

User

Code:

PIN

The User code operates the lock. Maximum number of user codes is 250 with Network Module;

without Network Module, maximum is 25 user codes. Note: When deleting User

code(s), screen will display

PIN

User Number (not

code) being deleted.

PIN

Volume Setting Mode:

Low (2)

The volume setting for

code verification is set to

by default; otherwise it can

PIN

be set to

or

for quiet areas.

High (1)

Silent (3)

Wrong Code Entry Limit:

After five (5) unsuccessful attempts at entering a valid

code,  the unit will shut

PIN

down and not allow operation.

Summary of Contents for YRD246

Page 1: ...tallation and Programming Instructions 246 446 YRD YRD x4 x2 x3 8 32 x 5 16 Machine screws 7 wood 8 32 machine x 20mm Combination screws M6x55mm Long through bolt Optional Network Module Before you begin for step by step installation instructions to register your product DOWNLOAD THE BILT APP ...

Page 2: ...P N Rev E YRL KFTSINSTL FUL 2 Preparing Door ...

Page 3: ...Rev E YRL KFTSINSTL FUL 3 O x4 1 d faut e 2 3 8 position 2 3 4 position Installing Latch Strike Plate Press Pull optional Bolt must be in retracted unlocked position Note horizontal orientation of mechanism ...

Page 4: ...P N Rev E YRL KFTSINSTL FUL 4 2 Installing Touchscreen Escutcheon Bolt must be in retracted unlocked position Note horizontal orientation of mechanism Outside of Door Inside of Door ...

Page 5: ...P N Rev E YRL KFTSINSTL FUL 5 x2 3 Installing Interior Mounting Plate Loosen screw to remove cover ...

Page 6: ...4 Attaching the Cable Assembly P N Rev E YRL KFTSINSTL FUL 6 ...

Page 7: ...P N Rev E YRL KFTSINSTL FUL 7 x3 5 Installing Interior Escutcheon ...

Page 8: ...3 Testing Operation Bolt must be in retracted unlocked position before installing batteries P N Rev E YRL KFTSINSTL FUL 8 ...

Page 9: ... 9 6 7 Installing Batteries Handing the Lock Batteries must be removed prior to removing and or inserting network module Welcome to Yale Real Living Lock automatically adjusts for proper handing Installing Optional Network Module ...

Page 10: ...10 8 Congratulations you ve installed the Yale Real Living Assure Lock Key Free Touchscreen Deadbolt 246 446 YRD YRD Continue with Programming Instructions to customize your product Installing Cover Tighten screw to replace cover ...

Page 11: ...st be created before any further programming PIN Max User Codes 250 with Network Module 246 Max User Codes 25 without 446 Max User Codes 12 without YRD YRD Lock Activation Speaker P Key Return to Previous Low Battery Indicator Lockout Mode Failsafe 9 volt Battery Connection Use Alkaline battery Exterior Escutcheon ...

Page 12: ...llation or after resetting the lock to factory PIN default Programming and use of lock is not possible until this step has been successfully completed Press Register Master Code Press the gear key to continue Press Enter a 4 to 8 digit code followed by PIN the gear key Registered P N Rev E YRL KFTSINSTL FUL 12 ...

Page 13: ...odes 25 without YRD YRD446 Max User Codes 12 without Enter Master code PIN Press Press Press Press Press Enter 4 8 digit code PIN Press Press code flashes Menu Mode enter number press the gear key to continue Enter 4 8 digit code PIN Adding more User Codes Press Press To end programming P N Rev E YRL KFTSINSTL FUL 13 ...

Page 14: ...Up to 250 Users Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ Code Chart User Name User Type PIN Code Unlocking Door with Code PIN User Enter Code PIN Press Duplicate if necessary ...

Page 15: ...The reset button see image at right is located beside the cable connector PCB 4 While pressing the reset button minimum of 3 seconds reinstall batteries Release reset button 5 Replace battery cover Upon reset Master Code creation is the only PIN option available and must be performed prior to any other programming of the lock Registration required Wrong Code Entry Limit 5 Times One Touch Locking E...

Page 16: ... optional Network Module installed this setting becomes available thru the Main Menu 7 and allows the lock to connect with a network controller One Touch Locking When the latch is retracted activating the keypad will extend the latch during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is in use any not disabled valid code will re lock the lock PIN Previou...

Page 17: ...tinue Complete Register Delete M 2 3 1 Join the Network Enable Disable English Spanish French Silent Low High Exit the Network Volume Setting Language Setting Mode Lockout Mode Network Module Setting Programming with Module Device Setup Digital Keys Transfer Data This function appears only with network module installed Default settings in bold This function appears only with Bluetooth version inst...

Page 18: ...if they respond when pressed Check batteries are installed and oriented correctly polarity in the battery case Check batteries are in good condition replace batteries if discharged Check to see if touchscreen harness is fully connected and not pinched Batteries may be completely discharged Batteries do not have enough power Replace batteries Check the door gaps for any foreign objects between door...

Page 19: ...lready made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed under the bolt see Fig A e Verify bolt is installed with correct side up Fig A Keypad numerics are scrolling Remove interior escutcheon and check to ensure that the wire harness lies flat against the back recessed area and is properly routed along the side ...

Page 20: ...d radio technician for help TV May contain FCC ID QBLE Q0 113 Model 113 A M256K BLE Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareillage numérique de la classe A répond à toutes les exigences de l interférence canadienne causant des règlements d équipement May contain IC BLE 5123A 113 Model 113 A M256K BLE...