INSTRUMENT OPERATION
- Simply aim the thermometer at the target and press
the 'Measure' button to display the surface temperature. The distance to target
ratio is 1:1 therefore the thermometer should be positioned as close to the target
as possible.
Please note:
Prolonged use at close range to a source of high or low
temperature may affect the accuracy of the instrument due to thermal radiation.
MIN/MAX
- First turn the instrument on by pressing the 'Measure' button, then
press the 'Mode' button once for maximum or twice for minimum. The 'MAX' or
ٔxXzٔǣƬȒȇɯǣǼǼˢƏɀǝِ¨ȸƺɀɀƏȇƳǝȒǼƳɎǝƺٔxƺƏɀɖȸƺٔƫɖɎɎȒȇٕɎǝƺɎǝƺȸȅȒȅƺɎƺȸɯǣǼǼ
display the minimum or maximum reading only.
LOCK
- The lock mode is particularly useful for continuous monitoring of
ɎƺȅȵƺȸƏɎɖȸƺɀِÁȒɖɎǣǼǣɀƺɎǝƺǼȒƬǸȅȒƳƺًˡȸɀɎɎɖȸȇɎǝƺǣȇɀɎȸɖȅƺȇɎȒȇƫɵȵȸƺɀɀǣȇǕ
the 'Measure' button, then press the 'Mode' button three times for the lock mode
ǔɖȇƬɎǣȒȇِÁǝƺٔn !kٔǣƬȒȇɯǣǼǼˢƏɀǝًɎǝƺȇȵȸƺɀɀɎǝƺٔxƺƏɀɖȸƺٔƫɖɎɎȒȇɎȒƬȒȇˡȸȅ
the lock measurement mode. The thermometer will continuously display the
temperature for up to 60 minutes or until the 'Measure' button is pressed. Press
the mode button to return to standard measurement.
°C/°F
ٮÁȒƬǝƏȇǕƺɎǝƺɎǝƺȸȅȒȅƺɎƺȸǔȸȒȅٔ۳!ٔɎȒٔ۳IٔȒȸǔȸȒȅٔ۳IٔɎȒٔ۳!ًٔˡȸɀɎɎɖȸȇ
the instrument on by pressing the 'Measure' button, then press the 'Mode'
ƫɖɎɎȒȇǔȒɖȸɎǣȅƺɀًɎǝƺٔ۳!ٔȒȸٔ۳IٔɀɵȅƫȒǼɯǣǼǼˢƏɀǝًȵȸƺɀɀɎǝƺٔxƺƏɀɖȸƺٔƫɖɎɎȒȇɎȒ
change the scale.
EMISSIVITY
- The IR-Pocket thermometer is supplied with a default emissivity of
0.95. The emissivity of the thermometer can be changed from 0.1 (10E) to 1 (100E).
Changes should only be carried out by experienced personnel. To change the
ƺȅǣɀɀǣɮǣɎɵًˡȸɀɎɎɖȸȇɎǝƺǣȇɀɎȸɖȅƺȇɎȒȇƫɵȵȸƺɀɀǣȇǕɎǝƺٔxƺƏɀɖȸƺٔƫɖɎɎȒȇًɎǝƺȇ
ȵȸƺɀɀɎǝƺٔxȒƳƺٔƫɖɎɎȒȇˡɮƺɎǣȅƺɀǔȒȸɎǝƺƺȅǣɀɀǣɮǣɎɵǔɖȇƬɎǣȒȇِٔחד0ٔɯǣǼǼˢƏɀǝȒȇɎǝƺ
LCD screen, press the 'Measure' button to adjust the emissivity value, then press
the 'Mode' button again to exit the set up screen. For information relating to the
ƺȅǣɀɀǣɮǣɎɵȒǔɀȵƺƬǣˡƬȅƏɎƺȸǣƏǼɀًȵǼƺƏɀƺɮǣɀǣɎȒɖȸɯƺƫɀǣɎƺȒȸƬȒȇɎƏƬɎɎǝƺ0ÁX³ƏǼƺɀ
ǔˡƬƺِ
Please note:
non-contact infrared thermometers are not recommended
for use in measuring the temperature of shiny or polished metals.
LED SPOT ALIGNMENT
- The LED indicator is not exactly the same as the
target size. To get the best measurement result, aim at the target within a
distance of about 2.5 cm.
X«ٳ¨ !k0Á
Infrared Thermometer
Operating Instructions
Product code:
814-060
Supplied by
Electronic Temperature Instruments Ltd
Worthing · West Sussex · BN14 8HQ
01903 202151 · sales@etiltd.com · etiltd.com
814-060/28.09.18
Yalitech Instruments
Santiago de Chile, Río Refugio 9648, Parque de Negocios ENEA, Pudahuel.
www.yalitech.cl · ventas@yalitech.cl · (+56 2) 28988221