Chapter 7 Installation
Figure 65: Dimensions of overlaps
•
The length of the overlap must be more than 3m.
•
The width of the overlap must be more than 2.5m.
Installing the peripheral wires
Important: The installation of the peripheral wire should take into account all the
principles set out in
Installing the peripheral wire
(page 48).
When connecting multiple wires to the charging station there are specific conditions that must
be respected.
Rule 1The start and finish wires should lie next to each other when they enter the station.
There should be no gaps in the loops. The correct and incorrect method of cabling is shown
below.
Rule 2The wires should not cross. The wires for one field should be taken around the other
field. The distance between them must be 600mm. If wires do cross, they must cross each
other at right angles (90°).
62 Turfmow 1000 Technician's Manual
Version: Release 3.5
Last updated: 2018-12-20