Chapter 9 Troubleshooting (Error messages)
Meaning / Reason
At least one wire, defining a field to be mowed, must be configured.
Solution
Check the installation configuration settings. See
78).
9.2.6 The robot has no parcel to mow. Please configure
least one parcel.
Scenario
Occurs when no parcel has been configured. At least one wire must be configured
defining a field to mow, and a parcel must be defined for each wire.
Solution
Check the installation configuration settings. See
78).
9.2.7 No peripheral signal!
Scenario
Occurs when the robot is unable to detect a valid magnetic signal.
Meaning / Reason
This can occur for a number of reasons which can be identified using the procedure
outlined below.
Solution
1.
Check that the robot is located inside the peripheral wire.
2.
Check that the charging station is powered up.
3.
Check all peripheral wire connections.
4.
Check the integrity of the peripheral wire using a multi-meter.
9.2.8 Wrong wire and parcels Configuration.
Scenario
Occurs when the robot has encountered a problem while mowing in a particular parcel.
When the robot re-starts it is not sure in which parcel it is located, and where it should
start mowing.
Solution
1.
Click
.
2.
Select
4. Mow now on ...
and select a parcel for the robot to mow in.
9.2.9 No station contact detected
Scenario
Occur if a positioning beacon is used to locate the charging station. If the robot has
executed the loopstep (so has detected the positioning beacon signal), but has not made
contact with the charge arms after 29m (by default), this error message will be shown.
Turfmow 1000 Technician's Manual
Version: Release 3.5
Last updated: 2018-12-20
135