Chapter 9 Troubleshooting (Error messages)
-
the motor
9.4.6 Motor blocked when going {0} to {1}mm
Scenario
Occurs after a command to change the cutting height has been issued, but the cutting
head can not move.
Meaning / Reason
The motor lifting the cutting head is not working.
Solution
1.
Remove the cover on the motor.
2.
Clean the lifting band.
3.
Inspect the lifting motor.
4.
Check the magnet and pulley.
9.4.7 STOP button issue detected
Scenario
Occurs when the Stop button is not operating correctly. The Stop button must be closed
when the robot is operating.
Meaning / Reason
The Stop button is determined to be closed by detecting a closed circuit between
magnets on the lid and relays in the body. If these magnets are and relays are not
connecting correctly the correct state of the lid can not be determined. This can arise due
to wide temperature fluctuations.
Solution
See
Correcting lid closure problems
(page 189).
9.4.8 Unexpected exit zone event
Scenario
Occurs when the robot did not exit from the station correctly, possibly turning in the wrong
direction.
Meaning / Reason
This can arise because:
-
there is problem with the configuration of the robot,
-
obstacles are impeding the exit from the station.
Solution
1.
If a "return to station" loop is being used, check that the robot is turning in the
correct direction in order to enter the station. The direction is set as a configuration
parameter in the
(page 114) .
Infrastructure
>
Parcels
. If the
phase on the loop circuit is incorrect, the robot will turn in the wrong direction to enter
and exit the station.
2.
Check the area around the charging station and remove any obstacles.
3.
If this does not rectify the situation, take photos/videos of the robot's behavior and
report the event to your dealer. (Note the date, time and robot serial number.
Turfmow 1000 Technician's Manual
Version: Release 3.5
Last updated: 2018-12-20
139