Chapter 7 Installation
-
Channel 9 is reserved for a station used for charging only and which does not generate
a signal.
7.1.8 Installing a channel board outside of the charging
station
When using multiple wires (fields), if a wire is located at a significant distance from the
charging station, it may be necessary to install a channel board closer to the field rather than
in the charging station. This can save on the total length of wire required. For an example of
this see
Complex garden and with station loop
(page 90)
It may also be necessary to install an external channel board, near the charging station, if
there is insufficient space in the charging station.
A specific box is provided for this. Product number YB-062-00015-3A.
Simply connect the two ends of the peripheral wire to the connections shown below.
Figure 37: External channel board
(1) Mains connection
(2) Peripheral wire connections
7.1.9 Installing an inductor in the charging station
If the total length of the peripheral wire for a field is less than 200m, it is necessary to install
an inductor in the charging station. This is especially important when using a small loop to
return the robot to the charging station.
Use Product number YB-039-00009 in the catalog.
46 Turfmow 1000 Technician's Manual
Version: Release 3.5
Last updated: 2018-12-20