Chapter 7 Installation
Figure 38: Inductor
The inductor must be placed in series with the peripheral wire.
One end must be connected to the station board. The other end is connected to the
peripheral wire.
7.1.10 Selection of charging station type (on the
positioning beacon board)
The figure below shows the bank of 8 switches on the positioning beacon board, and the
direction used for ON and OFF.
Figure 39: Charging station type switches
Switch
1
2
3
4
5
6
7
8
Purpose
Not used
Not used
TM2000
station
Ball
Picker
station
TM1000
station
Charge
Drop
station
Not used
Turfmow 1000 Technician's Manual
Version: Release 3.5
Last updated: 2018-12-20
47