170
Chapter 14—Scene Memories
DM1000 Version 2—Owner’s Manual
Recalling Scenes Safely
When a Scene is recalled, all mix parameters are set accordingly. However, in some situa-
tions,
you can retain the current settings of certain parameters
on certain channels by
using the
Recall Safe function
. You can set the Recall Safe function parameters for each
Scene individually or for all Scenes globally.
To set the Recall Safe function, press the DISPLAY ACCESS [SCENE] button repeatedly
until the Scene | Rcl Safe page appears.
A
Global Recall Safe
When this check box is checked, Recall Safe settings stored in Scene memories are
ignored and the current settings are retained.
B
SAFE
This parameter enables or disables the Recall Safe function.
C
MODE
The following MODE buttons determine which Safe channel parameters will remain
unaffected by Scene recalls. The MODE buttons correspond to the following parame-
ters:
•
ALL
................................ All parameters
•
FADER
........................... Channel faders
•
ON
.................................. Channel On/Off parameters
•
PAN
................................ Channel Pan parameters, Stereo Out balance
•
EQ
.................................. Channel EQ parameters
•
COMP
............................ Channel Comp parameters
•
GATE
............................. Channel Gate parameters
•
AUX
............................... Channel Aux Send levels, Pre/Post
•
AUX ON
........................ Aux Send On/Off parameters
•
DELAY
........................... Channel Delay parameters
•
ROUTING
.................... Channel Routing parameters
D
RECALL SAFE CHANNEL section
This section enables you to select which channels will remain unaffected by Scene
recalls, including Input Channels 1–48, Bus Outs 1–8, Aux Outs 1–8, Stereo Out, each
Group Master, internal effects, USER DEFINED Remote layers, HA (AD8HR/AD824),
and plug-in effects. The Recall Safe function is effective on channels and functions for
which the buttons are turned on.
Tip:
The ALL button is mutually exclusive of the other buttons.
2
3
4
1
Summary of Contents for 006IPTO-F0
Page 42: ...42 Chapter 3 Operating Basics DM1000 Version 2 Owner s Manual ...
Page 52: ...52 Chapter 4 Connections and Setup DM1000 Version 2 Owner s Manual ...
Page 92: ...92 Chapter 7 Bus Outs DM1000 Version 2 Owner s Manual ...
Page 108: ...108 Chapter 8 Aux Sends DM1000 Version 2 Owner s Manual ...
Page 146: ...146 Chapter 11 Surround Functions DM1000 Version 2 Owner s Manual ...
Page 214: ...214 Chapter 16 Automix DM1000 Version 2 Owner s Manual ...
Page 385: ...DM1000 Block Diagram ...