Program Change Scene Recall
227
01V—Owner’s Manual
Program Change Scene Recall
When a MIDI Program Change message is received, a mix scene is recalled in accor-
dance with the scene memory to Program Change assignment table. Likewise, when a
mix scene is recalled, the 01V transmits a Program Change message that can be used to
recall a mix scene on another 01V or recorded to a MIDI sequencer for automated scene
recall. See “Recalling Mix Scenes Using MIDI Program Change Messages” on page 188.
Initially, scene memories 1 through 99 are assigned sequentially to Program Changes 1
through 99 as listed in the “Scene Memory to Program Change Table” on page 273,
although these assignments can be edited on MIDI page 2. These assignments are used
for both transmission and reception, so if Program Change #10 is assigned to scene
memory 20, the 01V recalls scene memory 20 when Program Change #10 is received,
and transmits Program Change #10 when scene memory 20 is recalled.
In order for the 01V to receive and transmit MIDI Program Change messages, the Pro-
gram Change Rx and Tx switches on MIDI page 1 must be turned on. See “MIDI Setup”
on page 224 for more information.
1. Use the [MIDI] button to locate MIDI page 2, as shown below.
2. Use the cursor buttons to select the PGM CHG. column, and then use the
PARAMETER wheel or [–1/DEC] and [+1/INC] buttons to select a Program
Change.
3. Use the right cursor button to select the NO. TITLE column, and then use
the PARAMETER wheel or [–1/DEC] and [+1/INC] buttons to select a
scene memory.
A scene memory to Program Change assignment table is
provided on page 273. To reset the assignments to their ini-
tial settings, use the cursor buttons to select the INITIAL-
IZE switch, and then press the [ENTER] button. The
dialog box shown here appears. Click OK to initialize.
The current scene memory to Program Change assignment table can be stored to an
external MIDI device, such as a MIDI data filer, using MIDI Bulk Dump. See “Bulk
Dump” on page 232 for more information.
If a scene memory is assigned to two or more Program Changes, the lowest Program
Change is transmitted when that scene memory is recalled.
If a scene memory that is not assigned to a Program Change is recalled, a System Exclu-
sive Parameter Change Scene Recall message is transmitted. See “System Exclusive
Parameter Control” on page 231 for more information.
Summary of Contents for 01V
Page 18: ...8 Chapter 1 Welcome to the 01V 01V Owner s Manual ...
Page 22: ...12 Chapter 2 Getting Started 01V Owner s Manual ...
Page 36: ...26 Chapter 3 Touring the 01V 01V Owner s Manual ...
Page 48: ...38 Chapter 4 Getting Around the User Interface 01V Owner s Manual ...
Page 116: ...106 Chapter 9 Aux Sends 01V Owner s Manual ...
Page 124: ...114 Chapter 10 Bus Outs 01V Owner s Manual ...
Page 170: ...160 Chapter 12 Effects 01V Owner s Manual ...
Page 192: ...182 Chapter 13 Dynamics Processors 01V Owner s Manual ...
Page 262: ...252 Chapter 18 System Examples 01V Owner s Manual ...
Page 270: ...260 Appendix A General 01V Owner s Manual ...
Page 282: ...272 Appendix B Specifications 01V Owner s Manual ...
Page 302: ...292 Appendix D Resources 01V Owner s Manual ...