ELEC
8-11
61U5H11
Electrical system
Checking the starter relay
(WH, E, ET)
1.
Remove the starter relay
1
.
2.
Connect the digital circuit tester leads to
the starter relay terminals.
3.
Connect the positive battery terminal to
the brown (Br) lead
2
, also connect the
negative battery terminal to the black (B)
lead
3
, and then check for continuity
between the starter relay terminals.
Replace the starter relay if there is no
continuity.
4.
Check that there is no continuity between
the starter relay terminals after discon-
necting a battery terminal from the brown
2
or black lead
3
. Replace the starter
relay if there is continuity.
3
2
6G480196
1
61U80030
Checking the neutral switch (WH)
1.
Check the neutral switch for continuity.
Replace if there is no continuity.
6F680140
a b
Br
Br
Switch Lead
color
position
Brown (Br)
Brown (Br)
Free
a
Push
b
61U5H11_08 05.10.7 3:02 PM Page 12