ELEC
8-17
61U5H11
Electrical system
Checking the hour meter
1.
Disconnect the hour meter coupler from
the wiring harness.
2.
Connect the positive battery lead to the
yellow (Y) terminal
a
, also connect the
negative battery lead to the black (B) ter-
minal
b
, and then check that the hour
meter displayed the all segments which
has been illuminated for 2 seconds.
Replace the hour meter if there is no illu-
minated.