61U5H11
9-6
9
8
7
6
5
4
3
2
1
Troubleshooting the power unit
Refer
Symptom 2
Cause 1
Cause 2
Checking step
to
page
Troubleshooting the PTT unit
Symptom 1: PTT unit does not operate
PTT relay does
not operate
Short, open, or loose
connection of the
wiring harness
Check the wiring har-
ness continuity.
*1
—
PTT relay malfunction
Check the PTT relay.
7-57
—
Short, open, or loose
connection of the PTT
motor lead
Check the PTT motor
lead.
*1
PTT motor does
not operate
Oil pressure
does not
increase
—
PTT motor malfunction
Disassemble and
check the PTT motor.
7-39
—
Blown fuse (20A)
Check the fuse (20A).
7-57
—
Loose connection of
the battery terminal
Check the battery ter-
minal.
—
—
Discharge battery
Check the battery.
3-14
—
Manual valve opened
Check the manual
valve for open.
—
Manual valve
malfunction
Insufficient PTT fluid
Add sufficient fluid.
3-10
—
PTT fluid leakage
Check the PTT unit for
leakage.
7-35
—
Clogged filter
Clogged fluid passage
Disassemble and
check the PTT unit.
7-44
7-50
—
*1
See the wiring diagram
61U5H11_09 05.10.11 9:16 Page 7
Summary of Contents for 115B
Page 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Page 4: ......
Page 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Page 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Page 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Page 255: ......