CHK
ADJ
3-11
61U5H11
Periodic check and adjustment
3.
If necessary, add sufficient fluid of the
recommended type until it overflows out
of the filler hole.
4.
Install the new O-ring, reservoir cap
2
,
and then tighten it to the specified torque.
Checking the tilt operation
(MH, WH, E)
1.
Set the tilt lock lever
1
to tilt position.
Check the outboard motor could tilting
up. Fully tilt the outboard motor up and
down a few times and check the entire tilt
range for smooth operation.
2.
Fully tilt the outboard motor down and set
the tilt lock lever
1
to lock position.
Check the outboard motor could not tilt-
ing up.
Recommended PTT fluid:
ATF Dexron
2
Reservoir cap
2
:
7 N·m (0.7 kgf·m, 5.2 ft·lb)
3.
Fully tilt the outboard motor up, then sup-
port it with the tilt stop lever
2
to check
the lock mechanism of the lever.
Lower unit
Checking the gear oil level
1.
Fully tilt the outboard motor down.
2.
Remove the check screw
1
, and then
check the gear oil level in the lower case.
NOTE:
If the fluid is at the correct level, the fluid
should overflow out of the filler hole when the
check screw is removed.
3.
If necessary, add sufficient gear oil of the
recommended type until it overflows out
of the check hole.
4.
Install the new gasket, check screw
1
,
and then tighten it to the specified torque.
69D10055
1
Recommended gear oil:
Hypoid gear oil
API: GL-4
SAE: 90
Check screw
1
:
9 N·m (0.9 kgf·m, 6.6 ft·lb)
61U30290
1
61U30295
1
69D30135
2
61U5H11_03 05.10.13 11:43 AM Page 12
Summary of Contents for 115B
Page 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Page 4: ......
Page 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Page 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Page 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Page 255: ......