Control function operation
29
There are three switches on the battery switch
assembly: the “START” switch, “HOUSE”
switch, and “EMERG PARALLEL” switch.
1
“HOUSE” switch (red)
2
“EMERG PARALLEL” switch (yellow)
3
“START” switch (red)
1
ON position (green)
2
OFF position (red)
In normal operation, keep the “START” and
“HOUSE” switches in the ON position.
Keep the “EMERG PARALLEL” switch in the
OFF position. This setting allows both batter-
ies to be charged automatically while the en-
gine is running.
NOTICE:
Do not turn the
“HOUSE” switch to the OFF position if the
boat is moored in the water as it will pre-
vent the bilge pump and anchor light from
functioning.
If the start battery is discharged, turn the
“EMERG PARALLEL” switch to the ON posi-
tion to start the engine. Once the engine is
started or the start battery is charged, turn the
“EMERG PARALLEL” switch to the OFF posi-
tion.
Battery switch (190 FSH)
The battery switch is located in the battery
compartment.
Turn the battery switch to the OFF position
when the boat will not be used again right
away. Turning the switch to the OFF position
will prevent the battery from being drained if
another electrical switch is accidentally left in
the on position.
NOTICE:
Do not turn the
battery switch to the OFF position if the
boat is moored in the water as it will pre-
vent the bilge pump and anchor light from
functioning.
1
Battery switch
H
O
U
S
E
S
T
A
R
T
EM
ER
G
PA
R
ALLEL
1
2
3