3 - 47
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a variable-current (voltage) charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
Charger
Ammeter
Adjust the voltage to obtain the
standard charging amperage.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING AND
CHARGING THE BATTERY”.
Adjust the charging voltage to
20
~
25 V.
Monitor the amperage for 3
~
5 minutes. Is the standard
charging amperage exceeded?
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check the
charging amperage after 5 hours. If there is any change in the amperage,
readjust the voltage to obtain the standard charging amperage.
Leave the battery unused for more than 30 minutes before measuring its
open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
NOTE:
Leave the battery unused for more
than 30 minutes before measuring
its open-circuit voltage.
NOTE:
Set the charging voltage to 16
~
17 V. (If the charging voltage is
lower, charging will be insufficient,
if it is higher, the battery will be
over-charged.)
YES
NO
YES
NO
Summary of Contents for 2004 Rhino 660 YXR660FAS
Page 1: ...LIT 11616 17 23 5UG F8197 10 YXR660FAS SERVICE MANUAL ...
Page 6: ......
Page 40: ...2 11 SPEC ENGINE SPECIFICATIONS Cylinder head tightening sequence ...
Page 55: ...2 26 SPEC COOLANT FLOW DIAGRAMS 1 Coolant outlet hose 2 Radiator inlet pipe 2 1 ...
Page 383: ...9 31 ELEC LIGHTING SYSTEM ...
Page 418: ......
Page 419: ......
Page 420: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...