The above warning is located on the top of the unit.

Explanation of Graphical Symbols

The lightning flash with arrowhead symbol 
within an equilateral triangle is intended to 
alert the user to the presence of uninsulated 
“dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude 
to constitute a risk of electric shock to 
persons.

The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the product.

IMPORTANT SAFETY INSTRUCTIONS

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8

Do not install near any heat sources such as 
radiators, heat registers, stoves, or other apparatus 
(including amplifiers) that produce heat.

9

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two 
blades with one wider than the other. A grounding 
type plug has two blades and a third grounding 
prong. The wide blade or the third prong are provided 
for your safety. If the provided plug does not fit into 
your outlet, consult an electrician for replacement of 
the obsolete outlet.

10

Protect the power cord from being walked on or 
pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the 
apparatus.

11

Only use attachments/accessories specified by the 
manufacturer.

12

Use only with the cart, stand, 
tripod, bracket, or table 
specified by the manufacturer, 
or sold with the apparatus. 
When a cart is used, use 
caution when moving the cart/
apparatus combination to 
avoid injury from tip-over.

13

Unplug this apparatus during lightning storms or 
when unused for long periods of time.

14

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

(UL60065_03)

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER (OR BACK). NO USER-SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR 
MOISTURE.

Summary of Contents for ACD1

Page 1: ...IT RU ES FR DE EN Owner s Manual Bedienungsanleitung Mode d emploi Manual de instrucciones Manuale di istruzioni...

Page 2: ...blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obso...

Page 3: ...t MUST be used Follow all installation instructions Failure to follow instruc tions could void your FCC authorization to use this product in the USA 3 NOTE This product has been tested and found to co...

Page 4: ...r to be caused by it immediately turn off the power switch disconnect the electric plug from the outlet and have the device inspected by qualified Yamaha service personnel If this device should be dro...

Page 5: ...ility Network Setup etc Always turn the power off when the device is not in use The performance of components with moving contacts such as switches volume controls and connectors deteriorates over tim...

Page 6: ...ates 8 Precautions when rack mounting the unit 9 Preparation 10 Connection Examples 11 Connections with the PC N or Tn series 12 Connections with the XP XM or XH series 13 Connections with controllers...

Page 7: ...e com Features of the ACD1 The ACD1 is an amplifier control device with the following features Monitor and control amplifiers from Amp Editor The ACD1 and amplifiers connected to the ACD1 can be monit...

Page 8: ...d amplifiers As of September 2009 the following amplifiers support connection with the ACD1 XP series XP7000 XP5000 XP3500 XP2500 XP1000 XM series XM4180 XM4080 XH series XH200 PC N series PC9501N PC6...

Page 9: ...ACD1 units Install a ventilation panel in this vacant space or leave it open to ensure adequate cooling Leave the back of the rack open and allow at least 10 cm of space between the rack and the wall...

Page 10: ...ng in an unexpected loud sound If you power off the ACD1 before your XP XM XH series amplifiers the amplifier s settings will return to their default state 1 Press the POWER switch to power on the ACD...

Page 11: ...ation at the maximum length cannot be guaranteed in some cases In the United States or Canada the Ethernet cables that connect the ACD1 to the computer or network switch should be STP cables in order...

Page 12: ...nector of the amplifiers as shown in the illustration It is not necessary to connect the amplifiers in order of their AMP ID but connecting them in this order will make it easier to determine the AMP...

Page 13: ...ACD1 and the amplifiers connected to the ACD1 If you connect an Ethernet compatible remote controller you must set the ACD1 IP Port number by using 6 Network Setup IP Ctrl Port on the ACD1 unit Altern...

Page 14: ...internal backup battery Firmware Ver Displays the ACD1 s firmware version LCD Backlight Selects whether the ACD1 s LCD backlight will be always lit ON or lit only during operation Auto OFF Panel Opera...

Page 15: ...the ACD1 s data was being saved Synchronize with Amp Editor once again to transmit the set tings from Amp Editor The backup battery has run down Check 5 Utility Battery for the state of the backup bat...

Page 16: ...alter Elektroger te kontaktieren Sie bitte Ihre rtliche Stadt oder Gemeindeverwaltung Ihren Abfallentsorgungsdienst oder die Verkaufsstelle der Artikel Information f r gesch ftliche Anwender in der Eu...

Page 17: ...ontacte a sus autoridades locales y pregunte por el m todo correcto de disposici n Informazioni per gli utenti sulla raccolta e lo smaltimento di vecchia attrezzatura Questo simbolo sui prodotti sull...

Page 18: ...ACD1 Owner s Manual MEMO...

Page 19: ...pe GmbH Siemensstra e 22 34 25462 Rellingen Germany Tel 49 4101 3030 Yamaha Corporation Asia Pacific Music Marketing Group Nakazawa cho 10 1 Naka ku Hamamatsu Japan 430 8650 Tel 81 53 460 2313 TURKEY...

Page 20: ...l Musical Instrument Division Yamaha Corporation 2009 Yamaha Corporation WM15360 909POCP 02B0 Printed in Japan Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http w...

Reviews: