PERIODIC MAINTENANCE AND ADJUSTMENT
7-28
7
To charge the battery
Have a Yamaha dealer charge the bat-
tery as soon as possible if it seems to
have discharged. Keep in mind that the
battery tends to discharge more quickly
if the vehicle is equipped with optional
electrical accessories.
ECA16521
NOTICE
_
To charge a VRLA (Valve Regulated
Lead Acid) battery, a special (con-
stant-voltage) battery charger is re-
quired. Using a conventional battery
charger will damage the battery.
_
To store the battery
1. If the vehicle will not be used for
more than one month, remove the
battery, fully charge it, and then
place it in a cool, dry place.
NOTICE:
When removing the
battery, be sure the key is
turned to “OFF”, then discon-
nect the negative lead before
disconnecting the positive
lead.
[ECA16302]
2. If the battery will be stored for
more than two months, check it at
least once a month and fully
charge it if necessary.
3. Fully charge the battery before in-
stallation.
NOTICE:
When in-
stalling the battery, be sure the
key is turned to “OFF”, then
connect the positive lead be-
fore connecting the negative
lead.
[ECA16840]
4. After installation, make sure that
the battery leads are properly
connected to the battery termi-
nals.
ECA16530
NOTICE
_
Always keep the battery charged.
Storing a discharged battery can
cause permanent battery damage.
_
ECAU0050
NOTICE
_
Do not ride the vehicle with the bat-
tery disconnected or with a low-
charged battery. This will cause
hard engine starting, decreased
headlight life, and the flasher lights
may not operate properly.
_
EAUU0851
Replacing the fuse
The fuse holder is located behind panel
A. (See page 7-8.)
If the fuse is blown, replace it as fol-
lows.
1. Turn the key to “OFF” and turn off
all electrical circuits.
2. Remove the starter relay cover by
removing the screw.
3. Pull the starter relay out.
1. Fuse cover
2. Screw
2
1
ZAUU0648