Prior to connecting the CRW-F1SX drive to the computer, set up the following using
the dip switch of the drive.
➀
SCSI ID Number
➁
Termination
➀
➀
➀
➀
SCSI ID Number
Each of the SCSI devices connected to the computer needs to be identified by its
own SCSI ID number from “0” to “7.” The SCSI ID number “7” is normally
reserved for the SCSI card. Therefore, assigning a SCSI ID number from “0” to
“6,” except for the ID numbers in use by other SCSI devices, to the CRW-F1SX
drive is recommended.
The dip switch of the CRW-F1SX has four switches, and use SW 1, SW 2, and
SW 3 (three switches from the left) to set the SCSI ID number. The switches are
set to ON when pulled down. Each switch set to ON counts each ID SELECT
number, and the sum total of the ID SELECT number determines SCSI ID number
as the SCSI ID table shown on page 13.
1 Set up the CRW-F1SX Drive
ID SELECT
TERMINATOR
1 24
Dip switch