CD preventive care
• This compact disc player is designed for use with
following types of disc only. Never attempt to load any
other type of disc into the unit. The unit will also play
8-cm (3-inch) compact discs.
• Compact discs are not subjected to wear during play,
but damage to the disc surface when the disc is being
handled can adversely affect the disc’s play.
• Do not use cleaning discs or warped discs. All of these
could damage the unit.
To prevent a malfunction of this unit
• Do not use any non standard shaped CD (heart, etc.)
available on the market, because it may damage the
unit.
• Do not use a CD with tape, seals, or paste on it, because
damage to the unit may result.
No!
Troubleshooting
If the unit fails to operate normally, check the following points to determine whether the fault can be corrected by the
simple measures suggested. If it cannot be corrected, or if the fault is not listed in the SYMPTOM column, disconnect the
power cord and contact your authorized YAMAHA dealer or service center for help. When taking the service, the MDX-
E100 or KX-E100 may be needed. For details, contact your authorized YAMAHA dealer or service center.
• Compact discs are not affected by small particles of
dust or fingerprints on their playing surface, but even so
they should be kept clean. Wipe by using a clean, dry
cloth. Do not wipe with a circular motion; wipe straight
outward from the center.
• Do not try to clean the disc’s surface by using any type
of disc cleaner, record spray, antistatic spray or liquid,
or any other chemical-based liquid, because such
substances might irreparably damage the disc’s surface.
• Do not expose discs to direct sunlight, high temperature
or high humidity for a long period of time, because
these might warp or otherwise damage the disc.
The unit does not switch ON when
the STANDBY/ON switch is pressed.
No sound from one speaker.
The sound suddenly goes off.
No sound from an external unit
connected with this unit or play does
not begin.
Sound distorted.
SYMPTOM
CAUSE
REMEDY
RX-E200 RECEIVER
Securely connect the power cord.
Connect properly.
Check the speaker wires are not touching each other
and then turn the unit back on.
Connect the cords properly. If the problem persists,
the cords may be defective.
Make a proper input source selection.
Connect the AC power cord of the component to an
AC outlet.
The AC power cord is not connected or not
completely connected.
Loose speaker connections.
The protection circuit has been activated
because of a short circuit, etc.
Incorrect cord connections.
Input source selection is not proper.
The component connected to this unit is
disconnected from AC outlet.