FMod (Filter Modulation Depth)
Set the amount by which the filter Cutoff frequency
changes when the Modulation Wheel is used.
❏
Settings:
0 ~ 127
■
AMod (Amplitude Modulation Depth)
Set the amount by which the amplitude modulation
changes when the Modulation Wheel is used.
❏
Settings:
0 ~ 127
CTL AT Control (AT Control Depth)
(Multi Plug-in Parts only)
Keyboard aftertouch can be used to control the
pitch/filter/amplitude parameters for each Multi Plug-
in Part (17 to 32).
■
Pitch
Set the amount (in semitones) by which the pitch
changes when aftertouch is applied.
❏
Settings:
-24 ~ +24
■
Filter
Set the amount by which the filter Cutoff frequency
changes when aftertouch is applied.
❏
Settings:
-64 ~ +63
■
Amp
Set the amount by which the output level
(amplitude) changes when aftertouch is applied.
❏
Settings:
-64 ~ +63
CTL AT Modulation (AT Modulation
Depth) (Multi Plug-in Parts only)
Keyboard aftertouch can be used to control the amount
of pitch/filter/amplitude modulation applied to each
Multi Plug-in Part (17 to 32).
■
PMod (Pitch Modulation Depth)
Set the amount by which the pitch modulation
changes when aftertouch is used.
❏
Settings:
0 ~ 127
CTLíAT Modulation) PMod FMod AMod
Part17 127 127 127
CTLíAT Control) Pitch Filter Amp
Part17 +24 +63 +63
■
FMod (Filter Modulation Depth)
Set the amount by which the filter Cutoff frequency
changes when aftertouch is used.
❏
Settings:
0 ~ 127
■
AMod (Amplitude Modulation Depth)
Set the amount by which the amplitude modulation
changes when aftertouch is used.
❏
Settings:
0 ~ 127
CTL AC Control (AC Control Depth)
(Multi Plug-in Parts only)
Control Changes (Assignable Controllers) can be used
to control the filter/amplitude parameters for each
Multi Plug-in Part (17 to 32).
■
Source
Set the MIDI Control Change number used to
control the Filter/Amp parameters.
❏
Settings:
off, 1 ~ 95
■
Filter
Set the amount by which the filter Cutoff frequency
changes when the controller (Source) is used.
❏
Settings:
-64 ~ +63
■
Amp
Set the amount by which the output level
(amplitude) changes when the controller (Source) is
used.
❏
Settings:
-64 ~ +63
CTL AC Modulation (AC Modulation
Depth) (Multi Plug-in Parts only)
Control Changes (Assignable Controllers) can be used
to control the amount of pitch/filter/amplitude applied
to each Multi Plug-in Part (17 to 32).
■
PMod (Pitch Modulation Depth)
Set the amount by which the pitch modulation
changes when the controller (Source) is used.
❏
Settings:
0 ~ 127
CTLíAC Modulation) PMod FMod AMod
Part17 127 127 127
CTLíAC Control) Source Filter Amp
Part17 04[FootCtrl] +63 +63