Preparation
I/O Card Installation
DME64N/DME24N Owner’s Manual
20
7.
Launch the DME Designer application, create configuration and transfer.
DME Designer setup, operation, and data transfer instructions can be found in the DME Designer Manual.
This completes preparation of the DME64N/24N system.
I/O Card Installation
The DME64N has four I/O card slots, and the DME24N has one I/O card slot. The number of audio input channels
available on the DME64N/24N can be increased by plugging the appropriate mini-YGDAI I/O card(s) into the available card
slot(s).
Compatible I/O Cards
As of April, 2007, Yamaha mini-YGDAI cards that can be used with the DME64N/24N are as follows:
The input/output numbers above apply to 44.1/48kHz operation.
(*)
In order to use three or four MY16-C cards, firmware V1.10 or later will be required.
If the serial number written on the upper surface of your DME64N is shown below, a hardware upgrade is needed.
KK, KL, KM, KN, KO, KP, KX, KY are the third and fourth digits of the serial number.
A fee is charged for the hardware upgrade.
For details, contact Yamaha customer support using the contact information located at the end of the “DME64N/24N Owner’s
Manual.”
For the latest information on what cards can be used with the DME64N/24N, visit the Yamaha Pro Audio
website at:
http://www.yamahaproaudio.com/
Card Name
Function
Input
Output
No. of Available Cards
DME64N
DME24N
MY8-AT
ADAT
8
8
4
1
MY8-TD
TDIF-1
8
8
4
1
MY8-AE
AES/EBU
8
8
4
1
MY4-AD
ANALOG IN
4
–
4
1
MY8-AD
ANALOG IN
8
–
4
1
MY4-DA
ANALOG OUT
–
4
4
1
MY8-AD24
ANALOG IN
8
–
4
1
MY8-AD96
ANALOG IN
8
–
4
1
MY8-DA96
ANALOG OUT
–
8
4
1
MY8-ADDA96
ANALOG IN/OUT
8
8
4
1
MY8-AE96S
AES/EBU
8
8
4
1
MY8-AE96
AES/EBU
8
8
4
1
MY8-AEB
AES/EBU
8
8
4
1
MY16-AT
ADAT
16
16
4
1
MY16-AE
AES/EBU
16
16
4
1
MY16-TD
TDIF-1
16
16
4
1
MY16-C
CobraNet
16
16
4(*)
1
MY16-CII
CobraNet
16
16
4
1
Summary of Contents for DME64N - Pro Audio
Page 1: ......