DME64N/DME24N Owner’s Manual
58
Error Messages
Message
Meaning
Action
Error messages
Cannot Select
No selectable items are available in the scene or
monitoring point list display.
Make the appropriate settings via the DME Designer
application.
Critical Battery
The internal battery is almost discharged. Your data may
be lost.
If you turn off power to the unit, the current settings may
be lost and reset to the default values. Stop operating the
unit, and contact a Yamaha dealer for battery
replacement.
Invalid Password
An invalid password has been entered.
Enter the correct password. If you have lost or forgotten
your password, contact a Yamaha dealer.
Log Buffer Full
Saving is not possible, since the Event Log saving area is
full.
Use DME Designer to delete the log.
Low Battery
The backup battery voltage is low.
This does not affect the operation of the unit. However, if
you continue using the unit, the settings may be lost and
reset to the default values. Contact a Yamaha dealer for
battery replacement at your earliest convenience.
No Battery
The internal battery is completely discharged or not
installed.
If you turn off the power to the unit, the current settings
will be lost and reset to the default values. Stop operating
the unit, and contact a Yamaha dealer for battery
replacement.
Param Access Err
The current setting cannot be displayed because the
parameter you attempted to operate does not exist. It is
possible that the component is not operating normally.
Save the current settings using DME Designer, execute
the initialization (Delete All Data). If the problem persists,
contact a Yamaha dealer.
Param Set Err
The current setting cannot be changed because the
parameter you attempted to operate does not exist. It is
possible that the component is not operating normally.
Save the current settings using DME Designer, execute
the initialization (Delete All Data). If the problem persists,
contact a Yamaha dealer.
Resume Data Lost!
Recall a Scene!
Current setting has been lost.
Recall the scene again.
If the problem persists, contact a Yamaha dealer.
Saving Failed
A save operation has failed.
Stop using the device immediately and contact a
Yamaha dealer.
Slots Overloaded
The current being used by all cards installed in I/O slots
exceeds the rated limit.
Make sure that the total current consumption of the cards
used does not exceed the limit.
Store Disable
The scene store parameter is set to “Disable.”
Set the scene store parameter to “Enable” via the Utility
display “Lock” page.
Storing Failed
Either the flash memory for storing data is full, or the file
system has been damaged.
Reduce the number of unused scenes. Alternatively,
delete the files saved via the File Storage function. If
deleting these items does not solve the problem, execute
the Delete All Data initialization. If the problem persists,
contact a Yamaha dealer.
Used by ExDevice
The connector selected by the Internal HA Ctrl
parameter or the MIDI Port parameter is already being
controlled by an external device (such as the PM5D).
Stop control from the external device. If it is being
controlled from the PM5D, turn off the CONNECT button
in the PM5D's DME CONTROL screen.
Used by HA Ctrl
The connector selected by the MIDI Port parameter is
already selected for internal head amp control from an
external device.
Set the Internal HA Ctrl parameter to something other
than the connector you want to select for the MIDI Port
parameter.
Used by MIDI
This cannot be set, since the connector selected by the
Internal HA Ctrl parameter is already used by the MIDI
function.
Set the MIDI Port parameter to something other than the
connector you selected for Internal HA Ctrl.
Status messages
Cable Disconnect
No network cable connected.
Make sure that a network cable is properly connected,
and that all network devices are functioning normally.
Cannot be assigned
No parameter assigned.
—
Cannot Store
The scene data is protected.
Set the protect parameter to “OFF” via the DME Designer
application.
CAS. In Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE IN] connector.
Make sure that the DME64N/24N and the card or
external source supplying the word clock are set to use
the same word clock.
CAS. Out Sync Err
The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE OUT] connector.
Make sure that the DME64N/24N and the card or
external source supplying the word clock are set to use
the same word clock.
Connection to Master
DME is Lost
Communication with the master DME device has been
interrupted.
Check that all cables are properly connected, and than
hubs, routers, and related devices are functioning
properly.