61U5H11
5-20
9
8
7
6
5
4
3
2
1
Power unit
Removing the electrical component
1.
Remove the cover
1
and disconnect the
coupler.
2.
Remove the hour meter
2
.
3.
Remove the stator assembly
3
, retainer
screw
4
, retainer
5
, pulser coil assem-
bly
6
, and Rectifier Regulator
7
.
4.
Remove the starter relay
8
and the PTT
relay assembly
9
.
5.
Remove the starter motor
0
.
3
6
61U50620
4
5
61U50640
0
2
61U50615
61U50600
61U50600
61U50610
1
61U50650
9
8
7
61U50630
61U5H11_05_1 06.2.10 17:22 Page 23