TRBL
SHTG
9-1
61U5H11
TRBL
SHTG
Troubleshooting
Troubleshooting the power unit
Troubleshooting the power unit (trouble code not available)
The trouble shooting when a trouble code is not available consists of the following 4 items.
Symptom 1: Specific trouble conditions.
Symptom 2: Trouble conditions of an area or individual part.
Cause 1: The content considered as the trouble factors of symptom 2.
Cause 2: The content considered as the trouble causes of cause 1 (described if necessary).
Symptom 1: Engine does not crank
Refer
Symptom 2
Cause 1
Cause 2
Checking step
to
page
Discharged battery
Starter motor
does not
operate
—
Check the battery for
electrolyte level, gravity
and voltage.
3-14
Loose connection of
battery terminal
—
Check the battery
terminal connection.
—
Short, open, or loose
connection in starter
motor circuit
—
Check the wiring har-
ness continuity.
*1
Starter relay
malfunction
—
Check the starter relay.
8-11
Blown fuse (20A)
—
Check the fuse (20A).
8-9
Starter motor
malfunction
—
Disassemble and
check the starter motor.
8-14
Engine start switch
malfunction
—
Check the engine start
switch.
8-10
Gear shift not in the
neutral position
—
Shift the remote control
lever to neutral.
3-7
*1
See the wiring diagram
Start-in-gear protection
system malfunction
Broken spiral spring
Manual starter
does not
operate
—
—
Check and adjust or
replace the start-in-
gear protection cable.
Disassemble and
check the spiral spring.
5-14
Gear shift not in the
neutral position
—
Shift the gear shift lever
to neutral.
3-7
3-4
61U5H11_09 05.10.11 9:16 Page 2
Summary of Contents for E115A
Page 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Page 4: ......
Page 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Page 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Page 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Page 255: ......