2-20
INSP
ADJ
ECONOMY SWITCH/PILOT LIGHT/
OVERLOAD WARNING LIGHT
ECONOMY SWITCH
1. Check:
•
Economy switch
1
È
120 V-60 Hz, 220 V-50 Hz
É
230 V-50 Hz
Checking steps:
•
Set the economy switch
1
to
“
ON
”
“
”
a
.
•
Start the engine.
•
Turn the switch of the electric device con-
nected to the AC outlet
“
ON
”
“
”
and
“
OFF
”
“
”
to check whether the
engine speed increases and decreases.
Does not change
→
Refer to
“
TROUBLE-
SHOOTING
”
in CHAPTER 3 and
“
GEN-
ERATOR SYSTEM
”
in CHAPTER 4.
1
a
1
a
SWL2050T
È
É
PILOT LIGHT
1. Check:
•
Pilot light
1
Checking steps:
•
Start the engine.
•
Check that the pilot light
1
turns on.
Refer to
“
GENERATOR SYSTEM
”
in
CHAPTER 4.
SWL2060T
1
OVERLOAD WARNING LIGHT
1. Check:
•
Overload warning light
1
2. Remove:
•
Control panel
•
Overload warning light connector
Refer to
“
CONTROL PANEL
”
in CHAP-
TER 3.
Checking steps:
•
Connect three dry cell batteries (1.5 V) to
the overload warning light lead.
•
Check that the overload warning light
1
turns on.
Does not turn on
→
Replace.
3. Install:
•
Overload warning light connector
•
Control panel
Refer to
“
CONTROL PANEL
”
in CHAP-
TER 3.
SWL2070T
1