G.F.C.I. Receptacle
WARNING
TO REDUCE THE CHANCE OF ELECTRICAL
SHOCK:
9
Do not attempt to operate electric devices if
the ground fault circuit interrupter reset button
pops out repeatedly during use.
9
Test the ground fault circuit interrupter during
the pre-operation checks according to the
maintenance instructions on page 50.
9
Remember that only receptacle labeled “GFCI”
have ground fault circuit interrupter protection.
The G.F.C.I. (Ground Fault Circuit Interrupter) shuts off
power to the protected receptacles if a ground fault
(electrical leak) is detected.
If the reset button pops out, the electric devices con-
nected into the receptacle may be faulty. If this hap-
pens, check the electric devices carefully. If the electric
devices appears to be in good condition, press the
reset button firmly until a click is heard. This will
restore power. If the reset button pops out again, dis-
connect all the electric devices immediately. Have the
electric devices inspected and repaired by a qualified
repairperson before attempting to use them again.