Connecting your UC 1500
1. Take the UC 1500 Base Unit, Dialer, and extension microphones
out of the box.
2. Connect the Dialer to the Base Unit, making sure to connect the
cable in the dialer port on the bottom of the UC 1500.
3. Connect the extension microphones to the two available extension
microphone ports on the bottom of the UC 1500.
4. Using the provided Ethernet cable, connect the UC 1500 to an
Ethernet jack providing power over Ethernet (PoE). If no PoE
enabled port is available, use an external PoE injector (e.g.
Revolabs 01-POEADP-KIT).
5. When booting up, the LEDs on the UC 1500 will change between red, green, and orange lights.
Once the UC 1500 is ready to use, the LEDs will turn off, the dialer screen will show the home
screen, and the device will emit a chime.
Connecting the UC 1500 to the VoIP Network:
There are multiple ways to configure the UC 1500 on your network:
1.
From the Dialer:
a. Press the Menu Button on the Dialer
b. Navigate to and Select the Settings Option
c. Select VoIP Settings from the Admin Settings Menu. The initial Administrator password to enter
the menu is 7386.
d. Configure the items in this menu per your call manager configuration
e. Reboot the system.
On successful configuration, the display will show the phone number associated with the line.
Contents
• 1 Base Unit
• 1 Dialer Unit
• 1 USB Cable, 6.56ft (2.0m)
• 1 Ethernet Cable, 25ft(7.62m)
• 2 Extension Microphones
• Quick Start Guide