Received and Transmitted:
64octet packets : 1
65-127octet packets : 166
128-255octet packets : 7
256-511octet packets : 1
512-1023octet packets : 0
1024-MAXoctet packets : 0
5.1.14 Clear frame counters
[Syntax]
clear
counters
ifname
[Parameter]
ifname
:
Interface name of LAN/SFP port or logical interface
Applicable interface
[Input mode]
priviledged EXEC mode
[Description]
Clears frame counter information for the interface specified by
ifname
.
If logical interface is specified as the
ifname
, the frame counters of all LAN/SFP port port units associated with that interface
are cleared.
[Example]
Clear the frame counters of LAN port #1.
SWR2311P#clear counters port1.1
5.1.15 Show SFP module status
[Syntax]
show
ddm
status
[Input mode]
unprivileged EXEC mode, priviledged EXEC mode
[Description]
Shows the status of the SFP module.
For each item, shows the current value, upper threshold value, and lower threshold value for each SFP port.
Item
Description
Temperature
Internal temperature of the module (°C)
Voltage
Voltage value (V)
Current
Current value (mA)
TX-Power
Strength of light produced (dBm)
RX-Power
Strength of light received (dBm)
[Example]
Show the status of the SFP module.
SWR2311P#show ddm status
Temperature High Alarm High Warning Low Warning Low Alarm
Interface (Celsius) Threshold Threshold Threshold Threshold
------------ ------------ ------------ ------------ ------------ ------------
port1.25 42.7 100.0 85.0 -40.0 -55.0
port1.26 - - - - -
port1.27 40.7 95.0 90.0 -20.0 -25.0
port1.28 Unsupported Unsupported Unsupported Unsupported Unsupported
Voltage High Alarm High Warning Low Warning Low Alarm
Interface (V) Threshold Threshold Threshold Threshold
------------ ------------ ------------ ------------ ------------ ------------
port1.25 3.37 3.62 3.46 3.13 2.97
122