If untagged is specified, untagged frames are used as voice traffic.
[Example]
Assign LAN port #1 as voice VLAN to VLAN #100.
SWR2311P(config)#interface port1.1
SWR2311P(config-if)#switchport voice vlan 100
6.2.14 Set CoS value for voice VLAN
[Syntax]
switchport
voice
cos
value
no
switchport
voice
cos
[Parameter]
value
:
<0-7>
CoS value to specify for connected device
[Initial value]
switchport voice cos 5
[Input mode]
interface mode
[Description]
Specify the CoS value to use for voice traffic by the connected device.
The connected device is notified of the setting via LLDP-MED in the following cases.
• Voice VLAN is specified for the corresponding port.
• LLDP-MED transmission and reception is possible for the corresponding port.
[Example]
Set the CoS value to 6 for using LAN port #1 as voice VLAN.
SWR2311P(config)#interface port1.1
SWR2311P(config-if)#switchport voice cos 6
6.2.15 Set DSCP value for voice VLAN
[Syntax]
switchport
voice
dscp
value
no
switchport
voice
dscp
[Parameter]
value
:
<0-63>
DSCP value to specify for connected device
[Initial value]
switchport voice dscp 0
[Input mode]
interface mode
[Description]
Specify the DSCP value to use for voice traffic by the connected device.
The connected device is notified of the setting via LLDP-MED in the following cases.
• Voice VLAN is specified for the corresponding port.
• LLDP-MED transmission and reception is possible for the corresponding port.
[Example]
Set the DSCP value to 63 for using LAN port #1 as voice VLAN.
SWR2311P(config)#interface port1.1
SWR2311P(config-if)#switchport voice dscp 63
Command Reference | Layer 2 functions |
169