ENGLISH
10
MY8-SDI-D Owner’s Manual
■
Dip Switches (SW2)
A
Emu Switch
If you set this switch to ON and the Native switch to OFF, the host device will
recognize the card as a Yamaha MY8-AD96 AD card.
B
Native Switch
If you use the card in a future host device that supports the Native mode, setting
this switch to ON and the Emu switch to OFF will enable you to make best use of
the MY8-SDI-D function.
Emu/Native Switch Settings
Leave the RSVD and TEST switches set to OFF. Otherwise, the unit will not
operate properly.
Emu
Native
Function
ON
OFF
MY8-AD96 Emulation mode
OFF
ON
MY8-SDI-D Native mode
ON
ON
Reserved
OFF
OFF
Reserved
About the Word Clock Settings
You cannot assign the MY8-SDI-D as the master clock.
If you need to synchronize the host device to a house sync signal (external digital
system), use the WORD CLOCK IN connector to set the master clock of the host
device to WORD CLOCK IN.
ON
1
2
3
4
5
6
7
SW2
ON
Emu
N a t i v e
RSVD
TEST
ON
1234
OFF
2
1