Input Channel Section
25
The VCA 1 ~ VCA 12 [CUE] switches function as group cue switches for all assigned input channels. When a VCA
master [CUE] switch is engaged it will light, while the [CUE] switches of all assigned channels will flash, and the signals
from those channels will be routed to the console’s cue (L&R, C) buses for monitoring.
The Mute Master Switches
Mute master switches [1] ~ [8] function as group mute switches for the assigned input channels.
Press any of the MUTE MASTER switches, [1] ~ [8], to mute the assigned channels. You can configure the channel [ON]
switches to either flash or go out entirely when muted, as described on page 25-1.
NOTE
Refer to the “Monitor Control Section” on page 40 for more details.
NOTE
If the mute safe function is on, the channel [RECALL SAFE] switches can be used to prevent specified channels in the group from being muted
when the assigned mute master switch is engaged (details on page 66). When the direct recall function is on and the [DIRECT RECALL]
indicator is lit, the mute master switches can not be used for group muting (details on page 71).
1
2
3
4
5
6
7
VCA
2
VCA
1
VCA Faders
Channel Faders
Channels 1 and 3 can be monitored by engaging either the
VCA 1 or VCA 2 [CUE] switch.
1
2
3
4
5
6
7
Mute Master Switches
Channel Faders
In this setup channels 1 and 3 can be muted by engaging either the mute master [1] or [2] switch.
Summary of Contents for PM 5000 Series
Page 1: ...Owner s Manual E ...