48
Monitor Control Section
The meter bridge also features independent dimmer
controls for the meters, panel switch illumination, and
gooseneck lamps, as well as a [LAMP OFF] switch for
the gooseneck lamps.
Confirmation LEDs are also provided for the phantom
power supply and other power-supply voltages, as well
as operation of the console and external power supply
cooling fans.
NOTE
If excessive temperature or abnormal voltages are detected in the
dedicated external PW5000 power supply unit the PW
CAUTION indicator will light as long as continued operation is
possible, but if operation becomes impossible the power supply
will automatically shut down. The FAN CAUTION indicator if
one or more of the PM5000’s internal cooling fans ceases to
operate. In either case have the unit(s) checked by qualified
service personnel as soon as possible.
LAMP
DIMMER
LAMP OFF
OUT METER
LED DIMMER
PANEL
LED DIMMER
Gooseneck lamp
dimmer.
Gooseneck lamp
off switch.
Bar-graph meter
dimmer.
Panel switch
dimmer.
PW
CAUTION
FAN
CAUTION
+48V
MASTER
ON
+48V
+12V
+16V
-16V
Phantom
power supply
and
other voltage
supplies.
External power supply
(lights when a problem
is detected).
Cooling fans
(lights when a problem
is detected).
Master phantom
power supply switch on.
Summary of Contents for PM 5000 Series
Page 1: ...Owner s Manual E ...