66
Digital Control Section
Recall Safe Select (Parameter No. U11)
Each input, VCA master, master out, and matrix out
channel on the PM5000 features [RECALL SAFE] and
[FADER SAFE] switches that can be used to protect all
of the corresponding channel’s settings or just the fader
setting from scene recall operations, allowing the
specified settings to be maintained while scene recall
operations only affect unprotected channels or settings.
This functions as the master ON/OFF switch for entire
recall safe system. There’s also a mute safe function for
all input channels which, when active, exempts the
channels on which the [RECALL SAFE] switch is
engaged from MUTE MASTER switch mute operation
when the channel is assigned to a mute group.
1
Press [ENTER] after selecting the above display and
it will become possible to select the target function:
select RCL SAFE (recall safe) or MUT SAFE (mute
safe) and press the [ENTER] key.
Recall Safe:
Enables (ON) or disables (OFF) the recall safe function
for all [RECALL SAFE] switches.
Mute Safe:
Enables (ON) or disables (OFF) the mute safe function
for all input-channel [RECALL SAFE] switches.
2
Use the [INC] and [DEC] keys to turn the selected
function ON or OFF.
Solo Enable (Parameter No. U12)
Enables or disables the console’s solo function. If
DISABLE is selected here the meter-bridge [SOLO
MODE] switch will have no effect. The setting of this
function cannot be changed while the solo mode is
engaged.
Press [ENTER] after selecting the above display and use
the [INC] and [DEC] keys to select ENABLE (solo
mode enabled) or DISABLE (solo mode disabled).
NOTE
Protecting input channels from mute operation using the
[RECALL SAFE] switch is not affected by the master recall safe
ON/OFF setting. Although the same [RECALL SAFE] switch is
used for both scene-recall and mute protection, the two functions
are essentially unrelated. If, for example, the recall safe master
setting is OFF but the mute safe function ON, engaging a
[RECALL SAFE] will protect the corresponding channel from
mute master operation but not from scene recalls.
R C L S A F E S E L
R C L S A F E : O N
M U T S A F E : O F F
NOTE
If the solo mode is engaged it will not be possible to change the
setting to “DISABLE”. If the solo mode is disengaged
“ENABLE” will begin flashing on the display and it will be
possible to change the setting as required.
S O L O E N A B L E
S O L O : D I S A B L E