PM5000 Self-diagnostic Function
The PM5000 automatically performs a battery of
internal tests when the power is turned on. If no
problems are encountered the scene number will appear
on the display and normal operation will be possible.
If a system or other internal error is found console
operation will be suspended and/or an error message will
appear on the display.
If an error message appears, refer to the Error Messages
on page 94.
Initializing the Internal Memory
If an error occurs during the self-diagnostic memory
check (above), normal operation can sometimes be
restored by initializing the internal memory (initial
factory setup).
The memory initialization procedure described below
can also be used to return the memory to a blank state
prior to re-programming for the next show or tour.
1
Turn the console power ON while holding the
[STORE] key to start the initialization procedure.
2
Press the alpha-numeric keypad [1] key to initialize
the memory.
Press the [3] key to abort the initialization operation.
3
Normal operation resumes once the memory has
been initialized.
NOTE
The scene memory, setup memory, and MIDI program change
table are all initialized by this operation. If you want to keep any
of the data be sure to save it to an external memory card before
initializing the memory.
I N I T
S U R E ? Y : 1 N : 3
E x e c u t i n g
I N I T . C A N C E L