17
DGX-630/YPG-635
GHL88M
Grease
(グリス)
Rubber contact
(接点ゴム)
GHL88M
End lug of white key
(白鍵のツメ部分)
Fig.11
(図 11)
16-2
When removing white keys numbered as A-1 and B-1
key and black key numbered as A#-1, remove two (2)
screws marked [270B] and then lift the back of the keys
and slide the black and white keys towards you. (Fig.10)
16-3
When removing the C7 key, remove a screw marked
[270C] and then lift the back of C7 key and slide it
towards you. (Fig.10)
*
When removing white key assembly and black key
assembly, be careful not to allow grease to attach to the
circuit board and rubber contacts, etc. (Fig.11)
16-2
白鍵A-1、
B-1鍵と黒鍵A#-1は、
[270B]のネジ2本を外し、
A-
1、
A#-1、
B-1鍵の後方を持ち上げてから、
手前にスライドさ
せて取り外します。(図10)
16-3
C7鍵は、
[270C]のネジ1本を外し、
C7鍵の後方を持ち上げ
てから、
手前にスライドさせて取り外します。(図10)
※
白鍵Ass'y、黒鍵Ass'yの取り外しの際、グリスが基
板や接点ゴム等に付かないように注意してください。
(図11)
16-4
Actuate Rubber
Remove the actuate rubber. (Fig.12)
16-4
駆動ラバー
白鍵(黒鍵)
の駆動ラバーを外します。(図12)
Actuate rubber
(駆動ラバー)
Remove in this way.
(取り出す)
Fig.12
(図 12)
16-5
Rubber Contact
Remove the black and white key assemblies for two
octaves related to the subject rubber contact.
The rubber contact can then be removed. (Fig.13, Fig.14)
*
Note that the rubber contact has a specific installation
direction.
*
One rubber contact fits for C#-C (for C-B keys).
16-5
接点ゴム
該当する接点ゴムの2オクターブ分の白鍵Ass'y、
黒鍵Ass'y
を外して、
接点ゴムを外します。(図13,図14)
※
接点ゴムには、向きがあります。
※
接点ゴムは、C#〜Cの一連です。(キーはC〜B)