ENGLISH
3
DC PARALLEL INPUT Connector
This connector is used to connect two PW800W units in
parallel. Two PW800W’s can be connected in this way to
ensure uninterrupted failsafe operation in the even that
one unit shuts down.
Use only the optional PSL120 Power Supply Link Cable
for this connection. Rotate the connector ring to the right
to connect, or to the left to disconnect.
4
AC IN Connector
Connect the included power cable here. First, connect
the power cord to the PW800W, then insert the power
cord plug into the AC outlet. Securely clamp the AC
power cord using the supplied cord clamp to prevent
accidental disconnection from the AC IN connector.
Be sure to use the included power cord. Use of
other cords may result in malfunction, heat
generation, or fire.
To attach the cord clamp:
5
GROUND Screw Terminal
For maximum safety be sure to securely attach a
confirmed ground line to this terminal. The included
power cable has a three-pin plug, so the unit will be
properly grounded if the AC outlet used is grounded. If
the AC outlet is not grounded be sure to properly connect
the GROUND terminal. Proper grounding not only
ensures safety, but it also guarantees minimum noise
from hum and interference.
Parallel-connected PW800W Power Supplies
PM5D, etc.
PW800W (Primary)
PW800W (Secondary)
Optional PSL120 Power Supply Link Cable.
DC
OUTPUT
DC
OUTPUT
DC PARALLEL
INPUT
7