background image

connection.  Client mode in the executive Elite is persistent, meaning that if the server 
goes down or the connection is lost for any reason, the Executive Elite will periodically 
ping the server until the connection is re-established, without requiring a reboot. 
If the Executive Elite is the server, only one device can login at a time.  The login 
username is 

revolabs

 and the password is 

elite

, both case sensitive.  The port 

number is the standard Telnet port 23. 
The Executive Elite can be configured for external mute on the External Control 
Configuration page of the local web UI.    When external mute is set to On, the 
Executive Elite base DSP will always pass audio, even when the microphones are 
muted.  In this case it is the responsibility of the installer to ensure that mute is 
performed in the external component of the installation. 
Instead of a Room Control System, the Executive Elite system can receive commands 
also from a DSP system.  In this case select the DSP from the list in the Processor 
drop-down menu. 

NOTE:

 

Both a control system and DSP cannot be connected to a Base Station as 
a serial control processor at the same time. When using a control system 
and DSP at the same time, DSP control is typically done from the room 
control system, with the Executive Elite either connected to the DSP or 
the Room Control System. 

Serial Command & Return Strings

 

The Serial Strings of an Executive Elite Base Station begin with the Argument and 
terminates with a Carriage Return. The Command String structure is as follows: 

[<Argument>] <Command> [ch <Channel  Number> <Value>] <CR> 

The argument is either ‘set’ or ‘get’.  While it is used on most commands, there are 
some command snot using the set and get argument.  They are liste din the table 
below. 
If specific microphone channels are affected by the command, the string ‘ch’ is 
followed by the microphone channel number, and the value which is sent (‘set’ 
command). 
All variable changes on any microphone or the Executive Elite Base Station will result 
in a Return String. A Return String will begin with “val” and terminate with a Carriage 
Return. Return Strings will be received for every value change that has taken place in 
the microphones or base station including changes that are a result of a Command 
String sent to the Executive Elite Base Station, but also for changes initiated from the 
microphone or the web interface or front panel interface. The Return String structure 
is as follows: 

val <Command> ch <Channel  Number> <Value> <CR> 

Summary of Contents for Revolabs Executive Elite 01-ELITEEXEC8

Page 1: ...abs Executive Elite Wireless Microphone System Room Control API Guide Models 01 ELITEEXEC8 01 ELITEEXEC4 03 ELITEEXEC8 EU 03 ELITEEXEC4 EU 03 ELITEEXEC8 TW 03 ELITEEXEC4 TW 03 ELITEEXEC8 JP 03 ELITEEXEC4 JP ...

Page 2: ...NS INC All rights reserved No part of this document may be reproduced in any form or by any means without express written permission from Yamaha Unified Communications Inc Product specifications are subject to change without notice ...

Page 3: ...3 Contents Using an Executive Elite with a Control System 4 Serial Command Return Strings 5 Channel Number 6 Examples 6 Legacy Command Strings 6 Command String Tables 7 Legacy Command Tables 12 ...

Page 4: ...e the Connection Mode that is being used Telnet or Serial RS 232 To use the Executive Elite with a RS 232 serial connection a serial connection must be established between the DB9 serial port and an external control system The baud rate configured in the Elite Web UI must match the baud rate of the external control system The pin out of the Executive Elite serial port is as follows To use an IP co...

Page 5: ...same time When using a control system and DSP at the same time DSP control is typically done from the room control system with the Executive Elite either connected to the DSP or the Room Control System Serial Command Return Strings The Serial Strings of an Executive Elite Base Station begin with the Argument and terminates with a Carriage Return The Command String structure is as follows Argument ...

Page 6: ...anmic ch 3 1 The following strings would turn off all microphones on the Elite Command shutdownmic ch A Return val shutdownmic ch A The following strings would retrieve the battery status of microphone 5 98 Command get batterystatus ch 5 Return val batterystatus ch 5 98 Legacy Command Strings Legacy Commands that were used in the Executive HD have been maintained in the Executive Elite to allow fo...

Page 7: ...ieve the given microphone s battery status get batterystatus ch channel number percentage chairmanmic get chairmanmic ch channel number Retrieve the given microphone s chairman state For response 0 non chairman 1 chairman val chairmanmic ch channel number 0 1 chairmanmic set chairmanmic ch channel number 0 1 Configure the given microphone s chairman state 0 non chairman 1 chairman val chairmanmic ...

Page 8: ...roup name groupcount get groupcount Retrieve the group count val groupcount group count groupmutetype get groupmutetype group name Retrieve group mute type 0 Individual mute 1 Tabletop mute 2 Push to talk val groupmutetype group name 0 1 2 groupmutetype set groupmutetype group name 0 1 2 Configure group mute type 0 Individual mute 1 Tabletop mute 2 Push to talk val groupmutetype group name 0 1 2 g...

Page 9: ...status ch channel number Retrieve the given microphone s current status 0 off 1 on 2 standby 3 charging 4 out of range 5 not paired 6 pairing 7 unpairing 8 updating val micstatus ch channel number status mictype get mictype ch channel number Retrieve the given s microphone s type 0 Wearable 1 Omni 2 Directional 3 XLR 4 Mini XLR 5 Gooseneck 10 Handheld 11 unknown val mictype ch channel number type ...

Page 10: ...ve component serial number val serialnumber base serial number shutdownmic shutdownmic ch channel number Power the microphone off shutdownmic ch channel number startupunmutegroup get startupunmutegroup group name Retrieve given group s unmute at startup state 0 mute at startup 1 unmute at startup val startupunmutegroup group name 0 1 startupunmutegroup set startupunmutegroup group name 0 1 Configu...

Page 11: ...equency values include 0 110 140 175 and 220 Hz property_change_legacy_mode notify property_change_legacy_mode 0 1 Notify client that the legacy mode has changed 0 legacy off 1 legacy on property_change_lock notify property_change_lock ch channel number 0 1 Notify client the given microphone s mute lock changed 0 unlocked 1 locked property_change_lowpass_filter notify property_change_lowpass_filte...

Page 12: ...re input gain values 80 100 set the gain from 20 to 0 db values 101 120 will all set the gain 0 db 1 modify gain by 1 2 modify gain by 1 0 set gain to 0 val gain ch channel number 0 1 2 80 120 gain get gain ch channel number Retrieve input gain for specified channel val gain ch channel number 80 120 lock set lock ch channel number 0 1 Turns Mic Lock on or off 0 Off 1 On val lock ch channel number ...

Page 13: ... val lock Mic lock status mute val mute Mic mute state 0 unmuted 1 self muted 2 muted 3 microphone off 4 microphone out of range 5 microphone charging pair val pair Channel pairing status 0 Inactive 1 Active type val type Mic type 1 Lapel Wearable 2 Omnidirrectional Tabletop 3 Directional Tabletop 4 XLR Adapter 5 Countryman Adapter Copyright 2018 Yamaha Unified Communications Inc MN ELITE ROOM CON...