Pre-Flight Inspection Items
3-7
YACS Warning Light (red)
If a malfunction is discovered on the helicopter while the YACS control is being configured or a flight is in
progress, the YACS warning light (red) illuminates or flashes in unison with the self monitor, and provides the
operator a description of the warning.
If this light illuminates or flashes during a flight, calmly take the appropriate actions in accordance with the
description of the warning.
Indication
Self Monitor Status
Meaning
Action
All OFF
No malfunction
OK to fly
All ON(*1)
“
”
flashing
YACS control is being config-
ured.
Wait until the configuration is
complete (approx. 10 sec). During
this time, check for blown bulb in
the YACS warning light.
One of the malfunc-
tion area indicators
illuminates
Control has been switched to
manual mode due to a mal-
function.
Calmly land the helicopter in a
safe area, contact your dealer to
report which indicator is lit on the
self monitor, and request a repair.
No display on self
monitor; thermo
sensor flashing
The slide servo has heated
up abnormally, or the thermo
sensor has a malfunction.
Calmly land the helicopter in a
safe area. If there is no indication
on the self monitor, take actions
described on page 3-6.
Only outer lights flash
(for 15 sec after starting
engine)
After the engine has started,
for 15 sec.
OK to fly after flashing has
stopped and all lights are OFF.
(See page 5-8.)
Only outer lights flash
(3 times)
“
”
illuminat-
ing
A high load has been applied
due to reasons
1
to
3
,
causing the engine speed to
drop or the rudder to move
considerably in one direction.
1
Excessive payload.
2
Rough maneuvering
3
Effects from strong wind,
etc.
1
Calmly land the helicopter in a
safe area and reduce the pay-
load. (See page 4-10.)
2
Operate the helicopter more
gently.
3
Fly at a wind velocity of 3 m/s
or less.
Only outer lights flash
(Continuous flashing)
If the lights flash more than 3
times, the stability in the rudder
direction will deteriorate.Turn the
OFF YACS control switch and turn
it back ON to recover from this
condition.
Only inner lights flash
“
”
is ON
The remaining fuel is below
specification level.
Calmly land the helicopter in a
safe area and refuel. (See page 4-
4.)
RMAX.book Page 7 Tuesday, January 17, 2012 3:06 PM