Troubleshooting
Owner’s Manual
18
Messages
Errors, warnings, and certain other types of information
are displayed via the Ri8-D/Ro8-D front panel indicators.
Messages are also displayed in the Dante Controller Error
Status field.
Each indicator lights or flashes as described below:
Error Messages
When an error occurs, the indicators for all channels will
flash until the error is resolved, and the SYSTEM indicators
will light and/or flash cyclically as shown in the chart below.
In that case, repair is required. Contact your Yamaha dealer.
Warning Messages
The indicators will light and/or flash as shown until the
cause is resolved.
Information Messages
The indicators will remain lit and/or flashing cyclically to
report the status.
No call-out
The indicator is off.
Light
The indicator remains lit steadily.
Flash
The indicator continues to flash.
Flash x2
The indicator flashes twice cyclically.
Flash x3
The indicator flashes three times cyclically.
SYSTEM
Indicators
Description
Possible Solution
An internal error has
occurred.
The device has
failed. Contact your
Yamaha dealer for
repair.
The MAC address
setting has been cor-
rupted and no com-
munication can
occur via Dante.
The internal mem-
ory has been cor-
rupted.
Use the front-panel
DIP switches to set
START UP MODE to
REFRESH, then
restart the unit. If the
problem persists
after setting START
UP MODE back to
RESUME, consult
your Yamaha dealer.
UNIT ID is not
unique.
Set a unique UNIT
ID number for the
Dante network.
The DIP switches are
not set correctly.
Check the DIP switch
settings, and set
them correctly.
Flash x2
Flash x3
Flash x3
Light
Light
Flash
SYNC Indicators
Description
Possible Solution
The word clock is not
set correctly.
Set the clock mas-
ter and sampling
frequency correctly
on the Ri8-D/
Ro8-D-native
device or in Dante
Controller.
Dante Network circuit
is broken.
Make sure that the
Ethernet cables are
not removed or
short-circuited.
Dante Network is wired
incorrectly.
(The devices are con-
nected in a ring net-
work, although the
DAISY CHAIN setting
has been selected, or
they are connected in a
daisy chain network,
although the REDUN-
DANT setting has been
selected, etc.)
Make sure that the
Ethernet cables are
connected cor-
rectly.
A non-GbE-compati-
ble device is con-
nected.
Remove the
non-GbE-compati-
ble device from the
Dante network.
The SECONDARY
connector has taken
over communications
during redundant net-
work operation.
Check the circuit
connected to the
PRIMARY connec-
tor.
An abnormality has
occurred on the circuit
connected to the SEC-
ONDARY connector
during redundant net-
work operation.
Check the circuit
connected to the
SECONDARY con-
nector.
SYNC Indicators
Description
Possible Solution
Synchronizing
Please wait until
the unit synchro-
nizes completely. It
may take up to 45
seconds to syn-
chronize com-
pletely.
Operating as the word
clock master
The unit is operat-
ing as the word
clock master.
Flash
Flash x2
Flash x3
Light
Light
Flash
Light
Flash x2
Light
Light
Light or
flash in
different
patterns
Flash
Summary of Contents for Ro8-D