RX-V550/HTR-5750
RX-V450/HTR-5740/DSP-AX450
25
RX-V550/HTR-5750
RX-V450/HTR-5740/DSP-AX450
When there is a history of protection
function due to abnormal DC output
DC出力異常によるプロテクション
履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
When there is a history of protection
function due to excessive heat sink
temperature
放熱器の異常温度によるプロテク
ション履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
Voltage display in %
電圧の%表示
Cause:
DC output of the power amplifier is abnormal.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 3 seconds later
and the power supply will be shut off.
Cause:
The temperature of the heat sink is excessively
high.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 500%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
原因: パワーアンプのDC出力が異常。
補足: 異常時の電圧の状態を、5Vを100%とした値で%表示し
ます。
異常状態のままパワーオンすると、3秒後にプロテクションがか
かり、電源が切れます。
原因:放熱器の温度が異常。
補足: 異常時の電圧の状態を、5Vを500%とした値で%表示し
ます。
異常状態のままパワーオンすると、1秒後にプロテクションがか
かり、電源が切れます。
* Additional causes of protection can be due to loose
connections, associated components, CPU, etc.
* For the protection voltage value, refer to DIAG menu
No.11 described later.
※ 前記の異常原因の他に、コネクターのはずれやCPU周辺など
に原因がある場合があります。
※ プロテクションの電圧値に関しては、後述のダイアグメニュー
No.11を参照してください。
• Display during menu operation
During the DIAG operation, the function at work is
indicated on the FL indicator. The contents displayed
during the function operation are described in the later
section on details of functions.
• History of protection function
When the protection function has worked, its history is
stored in memory with a backup. Even if no abnormality
is noted while servicing the unit, an abnormality which
has occurred previously can be defined as long as the
backup data has been stored.
The history of the protection function is cleared when
DIAG is cancelled by selecting PRESET RESERVED
(Memory initialized) of DIAG menu No.10 or when the
backup data is erased.
● プロテクションの履歴
プロテクションが働いた場合、履歴をバックアップして記憶し
ています。サービスのときに異常が認められなくても、バック
アップが残っていれば、お客様のところで起きた異常を区別で
きます。
プ ロ テ ク シ ョ ン の 履 歴 は 、 ダ イ ア グ メ ニ ュ ー N o . 1 0 で
PRESET RESERVED
(メモリーの初期化)
を選んでダイアグ
を解除した場合や、バックアップが消えたときにはクリアされ
ます。
● メニュー動作中の表示
ダイアグ中、本体のFLディスプレイに動作中の機能が表示されま
す。機能動作中の表示内容については、後述の機能詳細で記述し
ます。