RX-Z11/DSP-Z11
2
RX-Z11/DSP-Z11
WALL
OUTLET
EQUIPMENT
UNDER TEST
AC LEAKAGE
TESTER OR
EQUIVALENT
INSULATING
TABLE
WARNING: CHEMICAL CONTENT NOTICE!
This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY
REASON WHAT SO EVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
1. Critical Components Information
Components having special characteristics are marked
s
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
●
Meter impedance should be equivalent to 1500 ohms shunted
by 0.15
µ
F.
●
Leakage current must not exceed 0.5mA.
●
Be sure to test for leakage with the AC plug in both polarities.
本機に搭載されているすべての基板およびハンダ付けによる接合
部は無鉛ハンダでハンダ付けされています。
無鉛ハンダにはいくつかの種類がありますが、修理時には下記の
ような無鉛ハンダの使用を推奨します。
・Sn+Ag+Cu(錫+銀+銅)
・Sn+Cu(錫+銅)
・Sn+Zn+Bi(錫+亜鉛+ビスマス)
注意:
無鉛ハンダの融点温度は通常の鉛入りハンダに比べ30〜40℃
程度高くなっていますので、それぞれのハンダに合ったハンダ
ごてをご使用ください。
All of the P.C.B.s installed in this unit and solder joints are
soldered using the lead free solder.
Among some types of lead free solder currently available,
it is recommended to use one of the following types for the
repair work.
• Sn + Ag + Cu (tin + copper)
• Sn + Cu (tin + copper)
• Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is
about 30
°
C to 40
°
C (50
°
F to 70
°
F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
About lead free solder /
無鉛ハンダについて
■
TO SERVICE PERSONNEL
For U model
“CAUTION”
“F1: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 4A,
125V FUSE.”
“F2: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 15A,
125V FUSE.”
For C model
CAUTION
F1: REPLACE WITH SAME TYPE 4A, 125V FUSE.
F2: REPLACE WITH SAME TYPE 15A, 125V FUSE.
ATTENTION
F1: UTILISER UN FUSIBLE DE RECHANGE DE MÉME TYPE DE 4A, 125V.
F2: UTILISER UN FUSIBLE DE RECHANGE DE MÉME TYPE DE 15A, 125V.
Summary of Contents for RX-Z11 - AV Receiver
Page 5: ...RX Z11 DSP Z11 5 RX Z11 DSP Z11 DSP Z11 J model RX Z11 A model...
Page 6: ...RX Z11 DSP Z11 6 RX Z11 DSP Z11 REAR PANELS RX Z11 U model RX Z11 C model...
Page 7: ...RX Z11 DSP Z11 7 RX Z11 DSP Z11 RX Z11 R model RX Z11 T model...
Page 8: ...RX Z11 DSP Z11 8 RX Z11 DSP Z11 RX Z11 K model RX Z11 A model...
Page 9: ...RX Z11 DSP Z11 9 RX Z11 DSP Z11 DSP Z11 B model DSP Z11 G E models...
Page 10: ...RX Z11 DSP Z11 10 RX Z11 DSP Z11 DSP Z11 L model DSP Z11 J model...
Page 39: ...39 RX Z11 DSP Z11 RX Z11 DSP Z11 MEMO MEMO...
Page 240: ...RX Z11 DSP Z11 241...
Page 241: ...RX Z11 DSP Z11 242...
Page 242: ...243 RX Z11 DSP Z11 RX Z11 DSP Z11 MEMO MEMO...
Page 243: ...RX Z11 DSP Z11...