69
En
Troubleshooting
English
AD
DITIONAL
INFO
RM
A
T
ION
■
AUTO SETUP
Before AUTO SETUP
During AUTO SETUP
Error message
Cause
Remedy
See
page
Connect MIC!
Optimizer microphone is not connected.
Connect the supplied optimizer microphone
to the OPTIMIZER MIC jack on the front
panel.
Unplug HP!
Headphones are connected.
Unplug the headphones.
—
Error message
Cause
Remedy
See
page
E-1:NO FRONT SP
Front L/R channel signals are not detected.
Check the front L/R speaker connections.
E-2:NO SUR.SP
A surround channel signal is not detected.
Check the surround speaker connections.
E-3:NOISY
Background noise is too loud.
Try running “AUTO SETUP” in a quiet
environment.
—
Turn off noisy electric equipment like air
conditioners or move them away from the
optimizer microphone.
—
E-4:NO MIC
The optimizer microphone was unplugged
during the “AUTO SETUP” procedure.
Connect the supplied optimizer microphone
to OPTIMIZER MIC jack on the front
panel.
E-5:USER CANCEL
The “AUTO SETUP” procedure was
cancelled due to user activity.
Run “AUTO SETUP” again.
E-6:INTERNAL ERROR
An internal error occurred.
Run “AUTO SETUP” again.