20
The following RPN messages can be received.
*1
Refer to 1.2.4
*2
'--' indicates that the setting value is ignored.
1.2.27 Assignable controller
By assigning a control change number of 0...95 to a part, the specified effect can be
controlled.
This device allows two control change numbers (AC1 and AC2) to be specified for each
part.
The following parameters specify the effect of AC1 and AC2.
• Multi Part Parameter
1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH
• Effect1 Parameter
7. AC1, AC2 VARIATION CONTROL DEPTH
(Valid if Variation Effect is assigned to a part as Insertion)
The AC1 control change number is specified by the Multi Part parameter AC1
CONTROLLER NUMBER, and the AC2 control change number is specified by the Multi
Part parameter AC2 CONTROLLER NUMBER.
1.3
Channel mode messages
These messages specify the basic operation of a part.
1.3.1 All Sound Off
This message silences all currently-sounding notes on the corresponding channel.
However, the settings of channel messages such as Hold will be maintained.
Control#
Parameter
Data Range
120
All Sound Off
0
1.3.2 Reset All Controllers
This message resets the following controllers to their default values.
The following data is not changed.
Parameter values specified by program change, bank select MSB/LSB, volume, pan, effect
send levels 1, 3, 4, RPN and NRPN.
Control#
Parameter
Data Range
121
Reset All Controllers
0
1.3.3 All Note Off
This message turns off all notes which are currently on for the corresponding part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until these are turned
off.
Control#
Parameter
Data Range
123
All Note Off
0
1.3.4 Omni Off
Perform the same processing as when All Note Off is received.
Control#
Parameter
Data Range
124
Omni Off
0
1.3.5 Omni On
Perform the same processing as when All Note Off is received.
Control#
Parameter
Data Range
125
Omni On
0
1.3.6 Mono
Perform the same processing as when All Sound Off is received, and if the value (mono
number) is in the range of 0...16, set the corresponding channel to Mode4* (m = 1).
Control#
Parameter
Data Range
126
Mono
0...16
*Mode4 is a state in which only channel messages on the specified channel will be
received, and notes will be sounded individually (monophonically).
1.3.7 Poly
Perform the same processing as when All Sound Off is received, and set the
corresponding channel to Mode3*.
Control#
Parameter
Data Range
127
Poly
0
*Mode3 is when channel messages will be received only on the specified channel, and will
be sounded polyphonically.
1.4
Program change
This message reports sound selection changes and changes the program number of the
receiving channel.
In order to include changes to the voice bank, Program Change and Bank Select
messages must be sent as a set (see 1.2.1).
When RevPROGRAM CHANGE = OFF for Multi Part Parameter, the program change for
that part is not received.
Not received when Receive Program Change in Native System Parameters is set to off.
1.5
Pitch bend
This message conveys movements of the pitch bender.
This message is generally used to modify the pitch of a part, but the depth of the following
seven effects can be controlled.
The effect of this message can be modified by the following parameters.
• Multi Part Parameter
1. BEND PITCH CONTROL
2. BEND FILTER CONTROL
3. BEND AMPLITUDE CONTROL
4. BEND LFO PMOD DEPTH
5. BEND LFO FMOD DEPTH
6. BEND LFO AMOD DEPTH
• Effect1 Parameter
7. BEND VARIATION CONTROL DEPTH
(Valid when Variation Effect is assigned to a part as Insertion)
By default, the Pitch Control effect is applied.
If the Multi Part parameter RECEIVE PITCH BEND CHANGE = OFF, that part will not
receive pitch bend messages.
1.6
Channel aftertouch (Receive only)
This message conveys the pressure which is applied to the keyboard after playing a note
in order to create tonal changes (for an entire MIDI channel).
The pressure can be controlled for each part. This message will affect the currently-
sounding notes.
The effect of this message will be determined by the settings of the following parameters.
• EMulti Part Parameter
1. CAT PITCH CONTROL
2. CAT FILTER CONTROL
3. CAT AMPLITUDE CONTROL
4. CAT LFO PMOD DEPTH
5. CAT LFO FMOD DEPTH
6. CAT LFO AMOD DEPTH
• Effect1 Parameter
7. CAT VARIATION CONTROL DEPTH
(Valid when the Variation Effect is assigned to a part as Insertion)
By default, there will be no effect.
If the Multi Part parameter RECEIVE CHANNEL AFTER TOUCH = OFF, that part will not
receive Channel Aftertouch.
NRPN
MSB LSB
Data Entry
*1
MSB LSB
Parameter name and value range
00H 00H
mm --
*2
Pitch bend sensitivity
mm:00-18H (0...+24 semitones)
Specify up to 2 octaves in semitone steps
00H 01H
mm ll
Fine tuning
mm ll: 00H 00H -100 cents
: :
mm ll: 40H 00H 0 cents
: :
mm ll: 7FH 7FH +100 cents
[Note] mm ll: 00H 7FH (= -87.5) cents is followed by 01H
00H (= -87.4) cents.
00H 05H
mm ll
Modulation Sensitivity
mm Specify in semitone steps
ll Specify in 100/128 cent steps
ex.
mm ll: 01H 00H ±1 semitone
mm ll: 00H 08H ±6.25 cents
00H 02H
mm --
Coarse tuning
mm:28H - 40H - 58H (-24...0...+24 semitones)
7FH 7FH
-- --
RPN Null
This sets RPN and NRPN numbers to an unset state.
Internal data is not affected.
Controller
Value
Pitch bend change
±0 (center)
Channel Aftertouch
0 (off)
Polyphonic Aftertouch
0 (off)
Modulation
0 (off)
Expression
127 (maximum)
Hold
0 (off)
Portamento
0 (off)
Sostenuto
0 (off)
Soft pedal
0 (off)
Portamento control
Reset the portamento source note number that was received.
RPN
Number unset, internal data is not affected.
NRPN
Number unset, internal data is not affected.