Appendix
Appendix E: Manual setting of Remote HA
HA parameters, such as the phantom power (+48V) and gain, of SB168-ES units can be
remotely controlled by performing the following procedures on the LS9.
Note: Two SB168-ES units are displayed as four AD8HR on the screen.
Using the PORT SELECT buttons, select the input ports
to which the external HA (SB168-ES) is connected in
groups of 8 channels.
Move the cursor to the EXTERNAL HA PORT
SELECT popup button, and press the [ENTER] key.
Repeatedly press the [RACK 5-8] key to access the
EXTERNAL HA screen.
Move the cursor to the COMM PORT box, use the dial
or the [DEC]/[INC] keys to select “SLOT1”, and press
the [ENTER] key.
Remote HA setting by loading SB_LS932.L9A session file
HA ID #1 – SB168-ES #1 Ch1-8 (Slot1 1-8)
HA ID #2 – SB168-ES #1 Ch9-16 (Slot1 9-16)
HA ID #3 – SB168-ES #2 Ch1-8 (Slot2 1-8)
HA ID #4 – SB168-ES #2 Ch9-16 (Slot2 9-16)