For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
111/273
(6)
After the position adjustment, check the following items and if there is no problem,
tighten the setscrews completely.
Y-axis MITSUTOYO scale head adjustment jig (t = 0.3mm): It can pass through.
Y-axis MITSUTOYO scale head adjustment jig (t = 0.5mm): It cannot pass through.
Note:
Basically, the position adjustment is performed only at one location.
(It is because the final adjustment is performed using the software (PC)).
Fig. C53
Note:
Finally, check the following items and if
there is no problem, fix it. Then, adjust
the parameters.
1.The scale head jig with thinkness
0.3mm can be entered without
problem.
2.The scale head jig with thinkness
0.5mm can not be entered.