For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
171/273
(2) Analog Gain Offset Input
Enter the analog gain offset value for the replaced new head.
Select "Sys. Setting", "Offset","Nozzle" and "Nozzle" in this order and enter the offset
value for the subject head.
4.13.2. Various Offset Adjustments
The teaching is performed in the following order.
Fig.D90
①
NL Origin Offset / Master Nozzle Level Offset
②
Chute Level (For Replacement)
③
PEC Recognition Camera & Beam Offset
④
Component Recognition Camera Offset
⑤
Head Rotation Axis Offset
⑥
Head Rotation Center/Base Mark Position Offset and Corn Recognition Offset
⑦
Fry Recognition Offset
⑧
Nozzle Inclination Offset
⑨
Head Offset A/B, For each angle, N1, For each speed reduction rate
Refer to "1.4.4 Offset in the Installation Operation (High-Speed Head)" in Chapter 1, for
various offset adjustments.
Fig.D89