4.15. Clamp Lever Change Procedure
4.15.1. Clamp Lever Removal
(1) Remove the cutter unit from the machine main body.
(Refer to Item 4.14.1, for the removal procedure.)
(2) Loosen the screw fixing the tape
leading cover and side covers and
remove them.
(3) Loosen the two set bolt (M5 x L13)
(two locations) for the clamp lever
mounting stay on the both sides and
remove the clamp lever.
* When removing, move the cutter
blade assembly to around the center
and remove the clamp lever.
* When removing, be careful of the
cutter blade.
①
②
③
Fig.D96
Fig.D97
Clamp Lever Stay Set Screw