6.3. Touch Panel Change and Adjustment Procedure
*
The panel adjustment is required in the following cases.
(1)
CPU1 is changed.
(2)
The coplanarity unit is attached or removed.
(3)
The touch panel is changed.
6.3.1. Touch Panel Removal Procedure
(1)
Disconnect the three cables connecting to the touch panel.
(2)
Remove the hexagon socket head cap bolts on the bracket fixing the touch panel and
remove the touch panel from the machine.
There is a fulcrum pin in the monitor fixing section.
When the monitor is to be removed, after removing the bolts in all three locations, remove the
monitor.
Remove the three cables in the specified locations.
Fig.F2
Fig.F3