For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
26/273
Note:
In the case that any of the 0402/0603 size components is not to be placed, omit the steps as follows.
[Delivery Adjustment/Teaching Flow Chart] (2/2)
(Normal)
[9] Head Rotation Center/Base Mark Position
Jig to be used : QFP Glass Jig : JG-0188, HA19C
[10] Fry Recognition Camera
Jig to be used : QFP Glass Jig : JG-0188, HA19C
[11] Nozzle Inclination
Jig to be used : QFP Glass Jig : JG-0188, HA19C
[12] Table
Jig to be used :Table Offset Jig, JG-0258
[13] Self-Calibration (Machine Inside CPK Measurement)
Name
Type
Q’ty
Jig to be used… 1) CPK Measurement Glass Jig PCB : JG-0195
×1 pcs
2) NOZZLE
: HG33C
×30 pcs
3) MIRROR_JIG_ASSY
: JG-0253
×1 pcs
4) Jig Chip _0603R
: CC731HTCF ×2 pcs
5) Double-Sided Tape (35mm × 50M) : No7692#12
×1 pcs
[Delivery Adjustment/Teaching Flow Chart (2)] (1/2)
There are no components with 0603 size or smaller.
[1] NL-Axis Origin Offset/Master Nozzle Level
Jig to be used: Master Nozzle (For high-speed head) : JG-0293
[3] Chute Level (For Replacement)
Jig to be used: Master Nozzle (For high-speed head) : JG-0293
[5] Pick-up Level
Jig to be used: Master Nozzle (For high-speed head): JG-0293
Automatic Height Teaching Jig: JG-0342
[6] PEC Recognition Camera & Beam Offset
Jig : No Required
[7] Component Recognition Camera Position
Jig to be used : QFP Glass Jig : JG-0188, HA19C
[8] Head Rotation Theta Axis
Jig to be used : QFP Glass Jig : JG-0188, HA19C
[9] Head Rotation Center/Base Mark Position
Jig to be used : QFP Glass Jig : JG-0188, HA19C
[13] Self-Calibration (Machine Inside CPK Measurement)
* The jigs are the same as above "Normal" case.