For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
48/273
(3)
Operation Flow
* In the case that some values are not within the range of company specified values;
The following causes might be considered.
(1) Device offset teaching error
(2) Head hardware trouble
Yes
No
Yes
No
No
The results are reported (Procedure Completed)
CPK Measurement Adjustment with BARON
CPK Measurement with BARON are the measurement results
within the range of company specified values for the
placement?
Are the measurement results of self-calibration within the
range of company specified values?
Manual Offset Tuning
(Check and Placement with Self-Calibration)
Self-Calibration Start
(Placement Accuracy Head Offset Teaching)
Device Offset Teaching
(Level, Component Recognition Camera Position, Head Rotation Center, etc.)
No